Details
Mica tape for fireproof cable is mainly used for the fire-resistant layers in fireproof cables.
It is made of mica paper and reinforcements bonded with silicone adhesive which has excellent resistance to heat.
Also, the OMF-8 has obtained the UL94 V-0 standard. (UL File No.E58537)
The DG88-AN coated with an adhesive having slight adhesiveness for work is used for cable joint sections.
Characteristics
- (1) Excellent electrical properties under high temperature conditions.
- (2) Uniform thicknesses and properties.
- (3) Highly flexible and easy to wind, which provides good fitting to conductors.
- (4) DG88-AN is easy to work with, as it contains adhesive on one side.
Use
- (1) Fireproof cables
- (2) Connection of fireproof cables
- (3) H-class dry type transformers
- (4) Insulation of highly heated parts of soldering iron, etc.
Composition, standard dimensions and general properties
MAT-1 | MAT-2B | OMF-8 | DG88-AN | |||||
---|---|---|---|---|---|---|---|---|
Mica | Mica paper based on phlogopite | |||||||
Binder | Silicone | |||||||
Reinforcement | Polyethylene film |
Double-sided polyethylene film |
Glass cloth | |||||
Standard dimensions | Thickness (mm) | 0.13 | 0.15 | 0.18 | 0.13 | 0.13 | 0.18 | 0.15 |
Width (mm) | 6 or more | 6 or more | 19 | |||||
Length (m) | 300, 600 (Negotiable) |
300, 600 (Negotiable) |
30, 50 | |||||
Product weight (g/m2) | 210 | 230 | 285 | 210 | 210 | 290 | ||
Binder content (wt%) | 10 or less | 10 or less | 10 or less | 30 or less | ||||
Tensile strength (N/10 mm wide) | 20 | 20 | 65 | 60 | ||||
Dielectric breakdown voltage (kV) | 6 | 6 | 1.8 | 2 | 1.5 | |||
Adhesion strength at room temperature (N/20 mm wide) | 0 (this is not an adhesive tape) | 1.5 | ||||||
Insulation resistance at high temperature (MΩ) | 1.0 or more | 1.0 or more | 1.0 or more |
*Measured in compliance with JIS C 2116.
*Adhesion strength of DG88-AN deteriorates in high-temperature atmosphere.
*Measurement method of insulation resistance at high temperature: SP method (Please contact us for more information.)
*The above values are examples from tests, and are not guaranteed values.